Square D - 20 Amp, 277 VAC, 1 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41398926
Brand: Square D
Model #: BDA140201
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
20
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 240 VAC, 2 Pole, Panel Mount Miniature Circuit Breaker
Item #: 56788912
Brand: Square D
Model #: QOU215VH5283
Exact Tooling IR#: 04Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
2
Terminal Connection Type
Ring Tongue
Mounting Type
Panel Mount
Voltage
240 VAC
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 240 VAC, 1 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG
Item #: 69660330
Brand: Square D
Model #: QOU160
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
60
Number of Poles
1
Terminal Connection Type
Box Lugs
Mounting Type
Panel Mount
Voltage
240 VAC
Wire Size (AWG)
14-2
Standards Met
CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 2000 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 56768286
Brand: Square D
Model #: RJF36200CU64AE1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
2000
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Screw
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
3/0
Standards Met
CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 40 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 56739543
Brand: Square D
Model #: HDL36040C
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
Standards Met
RoHS Compliant
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 25 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 69647709
Brand: Square D
Model #: HGL36025
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
25
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 250 Amp, 690 VAC, 4 Pole, Backplate, Fixed Mount Molded Case Compact Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 161mm High x 140mm Wide
Item #: 56738974
Brand: Square D
Model #: LV431130
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Compact Circuit Breaker
Amperage
250
Number of Poles
4
Breaking Capacity
15 kA @ 500 VAC; 20 kA @ 440 VAC; 20 kA @ 480 VAC; 25 kA @ 380/415 VAC; 40 kA @ 220/240 VAC; 40 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Backplate; Fixed Mount
Voltage
690 VAC
Durability
20000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-31
Overall Height (mm)
161
Overall Width (mm)
140
Standards Met
CSA; EN/IEC 60947-2; NEMA AB1; RoHS Compliant; UL 508; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 125 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56745680
Brand: Square D
Model #: HJP36125
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
125
Number of Poles
3
Breaking Capacity
25 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG
Item #: 56765258
Brand: Square D
Model #: LJL36250U31X
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
250
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
2
Standards Met
CCC; CSA; IEC; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 125 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41383480
Brand: Square D
Model #: BGA24125Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
125
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 70 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 56739766
Brand: Square D
Model #: HDL26070C
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
70
Number of Poles
2
Breaking Capacity
14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 125 Amp, 240 VAC, 2 Pole, Bolt On Miniature Circuit Breaker - 4-2/0 AWG
Item #: 42791657
Brand: Square D
Model #: QOB2125
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
125
Number of Poles
2
Terminal Connection Type
Box Lugs
Mounting Type
Bolt-on
Voltage
240 VAC
Wire Size (AWG)
4-2/0
Standards Met
CSA; RoHS Compliant; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 30 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41400391
Brand: Square D
Model #: BJL36030LU
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
30
Number of Poles
3
Breaking Capacity
100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 1000 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 56762503
Brand: Square D
Model #: PGL36100CU31A
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
1000
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
3/0
Standards Met
CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 0.5 Amp, 500 VDC, 2 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG
Item #: 46117578
Brand: Schneider Electric
Model #: M9U21270
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
0.50
Number of Poles
2
Breaking Capacity
20 kA @ 220 VDC; 10 kA @ 440 VDC; 6 kA @ 500 VDC; 5 kA @ 12-500 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
500 VDC
Wire Size (AWG)
18-4; 18-6; 18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 35 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56748205
Brand: Square D
Model #: HGP36035
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
35
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 20/20 Amp, 120 VAC, 2 Pole, Plug In Type BD Duplex Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG
Item #: 00105437
Brand: Eaton Cutler-Hammer
Model #: BD2020
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type BD Duplex Circuit Breaker
Amperage
20/20
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
120 VAC
Wire Size (AWG)
14-4
Standards Met
NEC 2008; NEC 2011; NEC 2014; UL Listed 67
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 70 Amp, 120/240 VAC, 3 Pole, Plug In Type CH Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-6 AWG
Item #: 00105007
Brand: Eaton Cutler-Hammer
Model #: CH370
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type CH Circuit Breaker
Amperage
70
Number of Poles
3
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-6
Standards Met
Federal Specification W-C-375; UL 489
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 50 Amp, 347 VAC, 1 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41399270
Brand: Square D
Model #: BDL16050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
50
Number of Poles
1
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 347VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 6.30 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 97mm Deep x 89mm High x 45mm Wide
Item #: 56806177
Brand: Schneider Electric
Model #: GV2L10
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Motor Circuit Breaker
Amperage
6.30
Number of Poles
3
Breaking Capacity
100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 4 kA @ 690 VAC
Tripping Mechanism
Magnetic
Terminal Connection Type
Screw
Mounting Type
Bolt-on; Clip
Voltage
690 VAC @ 50/60 Hz
Durability
100000 Cycles
Maximum Operating Temperature (F)
140
Minimum Operating Temperature (F)
-4
Overall Depth (mm)
97
Overall Height (mm)
89
Overall Width (mm)
45
For Use With
TeSys GV2
Standards Met
Bureau Veritas; CCC; CSA; DNV; GL; IEC 60947-2; LROS; RINA
2% Off All Online Orders
Use Code: 2%OFF