Square D - 80 Amp, 480Y/277 V, 3 Pole, Bolt On Miniature Circuit Breaker - 18 kA Breaking Capacity, 12, 14 AWG
Item #: 69660801
Brand: Square D
Model #: EDB34080
Exact Tooling IR#: 04
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
80
Number of Poles
3
Breaking Capacity
18 kA
Terminal Connection Type
Lug
Mounting Type
Bolt-on
Voltage
480Y/277 V
Wire Size (AWG)
12; 14
For Use With
NF Panelboard
Standards Met
CSA; HACR Rated; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 0.25 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide
Item #: 56805963
Brand: Schneider Electric
Model #: GV2ME026
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Motor Circuit Breaker
Amperage
0.25
Number of Poles
3
Breaking Capacity
100 kA @ 230/240 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 100 kA @ 690 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Bolt-on; Clip
Voltage
690 VAC @ 50/60 Hz
Durability
100000 Cycles
Maximum Operating Temperature (F)
140
Minimum Operating Temperature (F)
-4
Overall Depth (mm)
78
Overall Height (mm)
89
Overall Width (mm)
45
For Use With
TeSys GV2
Standards Met
ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 22 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide
Item #: 56837586
Brand: Square D
Model #: QOUR115VH
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
1
Breaking Capacity
22 kA @ 120/240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Pressure Plate
Mounting Type
DIN Rail Mounted; Flush Mount; Surface Mount
Voltage
120/240 VAC
Wire Size (AWG)
14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch)
2.9200
Overall Depth (mm)
74
Overall Height (mm)
103
Overall Height (Decimal Inch)
4.0500
Overall Width (mm)
19
Overall Width (Decimal Inch)
3/4
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41399676
Brand: Square D
Model #: BDA24060Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
60
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41400607
Brand: Square D
Model #: BJL26060
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
60
Number of Poles
2
Breaking Capacity
100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 20 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 22 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide
Item #: 56787948
Brand: Square D
Model #: QOUR120VH
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
20
Number of Poles
1
Breaking Capacity
22 kA @ 120/240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Pressure Plate
Mounting Type
DIN Rail Mounted; Flush Mount; Surface Mount
Voltage
120/240 VAC
Wire Size (AWG)
14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch)
2.9200
Overall Depth (mm)
74
Overall Height (mm)
103
Overall Height (Decimal Inch)
4.0500
Overall Width (mm)
19
Overall Width (Decimal Inch)
3/4
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 100 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG
Item #: 41399643
Brand: Square D
Model #: BDA24100Y1
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
100
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
I-Line; Lug
Mounting Type
Panel Mount
Voltage
480Y/277 VAC
Wire Size (AWG)
14-2/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 1200 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 25 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 8.05 Inch Deep x 16.16 Inch High x 8.27 Inch Wide
Item #: 56761927
Brand: Square D
Model #: PJP36120U31AAB
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
1200
Number of Poles
3
Breaking Capacity
25 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600 VAC
Wire Size (AWG)
3/0 (Aluminum); 3/0 (Copper)
Overall Depth (Decimal Inch)
8.0500
Overall Height (Decimal Inch)
16.1600
Overall Width (Decimal Inch)
8.2700
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 200 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 87.4mm Deep x 191mm High x 104.7mm Wide
Item #: 56743834
Brand: Square D
Model #: JGF36200
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
200
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Busbar
Mounting Type
Panel Mount
Voltage
600 VAC
Maximum Operating Temperature (F)
104
Overall Depth (Decimal Inch)
3.4400
Overall Depth (mm)
87.40
Overall Height (mm)
191
Overall Height (Decimal Inch)
7.5200
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met
CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 250 Amp, 240 V, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 240 VAC Breaking Capacity
Item #: 49753825
Brand: Square D
Model #: Q4L3250
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
250
Number of Poles
3
Breaking Capacity
25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
240 V
Standards Met
CCC; CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 63 Amp, 440 VAC, 4 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 72mm Wide
Item #: 56838097
Brand: Schneider Electric
Model #: M9F11463
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
63
Number of Poles
4
Breaking Capacity
10 kA @ 400-415 VAC; 20 kA @ 230-240 VAC; 6 kA @ 440 VAC
Tripping Mechanism
Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
440 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
18-2
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
72
Overall Width (Decimal Inch)
2.8347
For Use With
Multi 9 Modular System
Standards Met
IEC Certified; UL Listed; UL Recognized
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 15 Amp, 125 VDC, 240 VAC, 1 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04882890
Brand: Eaton Cutler-Hammer
Model #: EHD1015L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
15
Number of Poles
1
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
125 VDC; 240 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
4-1/8
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41396904
Brand: Square D
Model #: BGL36015
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
15
Number of Poles
3
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 16 Amp, 480Y/277 Volt, 3 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46120374
Brand: Schneider Electric
Model #: M9F23316
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60SP - Supplementary Protection
Amperage
16
Number of Poles
3
Breaking Capacity
14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
2.1300
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 2000 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG
Item #: 49753973
Brand: Square D
Model #: RGF36200
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
2000
Number of Poles
3
Breaking Capacity
18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Screw
Mounting Type
Panel Mount
Voltage
600 VAC
Wire Size (AWG)
3/0
Standards Met
CSA; IEC; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 1600 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 25 kA at 600 VAC Breaking Capacity, 14.49 Inch Deep x 16.24 Inch High x 16.54 Inch Wide
Item #: 56761406
Brand: Square D
Model #: JF36160U44AABJK
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
1600
Number of Poles
3
Breaking Capacity
25 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Terminal Nut
Mounting Type
Unit Mount
Voltage
600 VAC
Overall Depth (Decimal Inch)
14.4900
Overall Height (Decimal Inch)
16.2400
Overall Width (Decimal Inch)
16.5400
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 63 Amp, 440 VAC, 3 Pole, Clip, DIN Rail Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 81mm High x 54mm Wide
Item #: 56786569
Brand: Square D
Model #: 25443
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
63
Number of Poles
3
Breaking Capacity
20 kA @ 440 VAC; 25 kA @ 400-415 VAC; 30 kA @ 125 VDC; 50 kA @ 125 VDC; 50 kA @ 230-240 VAC; 60 kA @ 250 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Tunnel
Mounting Type
Clip; DIN Rail Mount
Voltage
440 VAC
Durability
20000 Cycles
Maximum Operating Temperature (F)
140
Minimum Operating Temperature (F)
-13
Overall Depth (mm)
73
Overall Height (mm)
81
Overall Width (mm)
54
For Use With
C60 Accessories; C60 Auxiliary
Standards Met
EN 60898; EN/IEC 60947-2
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 1200 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 65 kA at 600 VAC Breaking Capacity, 14.49 Inch Deep x 16.24 Inch High x 16.54 Inch Wide
Item #: 56761323
Brand: Square D
Model #: RKF36120
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
1200
Number of Poles
3
Breaking Capacity
65 kA @ 600 VAC
Tripping Mechanism
Electronic
Terminal Connection Type
Terminal Nut
Mounting Type
Unit Mount
Voltage
600 VAC
Overall Depth (Decimal Inch)
14.4900
Overall Height (Decimal Inch)
16.2400
Overall Width (Decimal Inch)
16.5400
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 20 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 54528369
Brand: Square D
Model #: HLL36020
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
20
Number of Poles
3
Breaking Capacity
100 kA @ 480 VAC; 125 kA @ 240 VAC; 20 kA @ 250 VDC; 50 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
Standards Met
RoHS Compliant
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 240 VAC, 3 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 3 Inch Wide
Item #: 04882510
Brand: Eaton Cutler-Hammer
Model #: HQP3040H
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
40
Number of Poles
3
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
240 VAC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
3
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF