Eaton Cutler-Hammer - 40 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 2 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 2 Inch Wide
Item #: 04882312
Brand: Eaton Cutler-Hammer
Model #: HQP2040
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
40
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
2
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 120/240 VAC, 3 Pole, Plug In Type CH Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-6 AWG
Item #: 00104976
Brand: Eaton Cutler-Hammer
Model #: CH340
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type CH Circuit Breaker
Amperage
40
Number of Poles
3
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-6
Standards Met
Federal Specification W-C-375; UL 489
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 240 VAC, 3 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 3 Inch Wide
Item #: 04882510
Brand: Eaton Cutler-Hammer
Model #: HQP3040H
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
40
Number of Poles
3
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
240 VAC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
3
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 240 VAC, 3 Pole, Plug In Type BR Circuit Breaker - Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG
Item #: 00105353
Brand: Eaton Cutler-Hammer
Model #: BR340
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type BR Circuit Breaker
Amperage
40
Number of Poles
3
Breaking Capacity
10 kA
Tripping Mechanism
Magnetic
Mounting Type
Plug-in
Voltage
240 VAC
Wire Size (AWG)
14-4
Standards Met
NEC 2008; NEC 2011; NEC 2014; UL Listed 67
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 250 VDC, 480 VAC, 2 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 2-3/4 Inch Wide
Item #: 04882957
Brand: Eaton Cutler-Hammer
Model #: EHD2040L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
2
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
2-3/4
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 250 VDC, 480 VAC, 3 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04883062
Brand: Eaton Cutler-Hammer
Model #: EHD3040L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
3
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
4-1/8
Overall Width (Decimal Inch)
4.1300
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 40 Amp, 277/480 VAC, 2 Pole, Bolt On Molded Case Circuit Breaker - Thermal Magnetic Trip, 10-1/0 AWG, 66.7mm Deep x 4 Inch High x 2 Inch Wide
Item #: 04882676
Brand: Eaton Cutler-Hammer
Model #: GHB2040
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
40
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
277/480 VAC
Wire Size (AWG)
10-1/0
Overall Depth (Decimal Inch)
2.6300
Overall Depth (mm)
66.70
Overall Height (mm)
101.60
Overall Height (Inch)
4
Overall Width (Inch)
2
Standards Met
CSA Listed; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 42 Circuits, 208/120 VAC, 225 Amp Main, 4 AWG, Indoor Main Lug Load Center - 3 Phase, 1 NEMA Rating, 14.31 Inch Wide x 3.88 Inch Deep x 34.13 Inch High
Item #: 00104158
Brand: Eaton Cutler-Hammer
Model #: CH42L3225G
Exact Tooling IR#: 04
Product Specifications
Load Center Type
Main Lug
Number of Circuits
42
Main Amperage
225
Number of Phases
3
Voltage
208/120 VAC
NEMA Enclosure Rating
1
Body Material
Steel
Circuit Breaker Installation Type
Plug-in
Overall Depth (mm)
98.40
Overall Depth (Decimal Inch)
3.8800
Overall Height (Decimal Inch)
34.1300
Overall Height (mm)
866.80
Overall Width (mm)
363-1/2
Overall Width (Decimal Inch)
14.3100
Wire Size (AWG)
4
Recommended Environment
Indoor
Standards Met
CSA E3624 Certified; CSA E51287 Certified; CSA File LR87196 Certified; EC Article 373.8; Federal Specification W-C 375 b/Gen; NEMA; UL 489; UL Listed File E11713; UL Listed File E8741
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 1 Pole, Plug In Type BR Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG
Item #: 00105205
Brand: Eaton Cutler-Hammer
Model #: BR150
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type BR Circuit Breaker
Amperage
50
Number of Poles
1
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-4
Standards Met
NEC 2008; NEC 2011; NEC 2014; UL Listed 67
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 2 Pole, Plug In Type BR Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG
Item #: 00105254
Brand: Eaton Cutler-Hammer
Model #: BR250
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type BR Circuit Breaker
Amperage
50
Number of Poles
2
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-4
Standards Met
NEC 2008; NEC 2011; NEC 2014; UL Listed 67
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 1 Pole, Bolt On Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 1 Inch Wide
Item #: 04882270
Brand: Eaton Cutler-Hammer
Model #: BAB1050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
50
Number of Poles
1
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
1
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 2 Pole, Bolt On Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 2 Inch Wide
Item #: 04882429
Brand: Eaton Cutler-Hammer
Model #: BAB2050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
50
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
2
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 2 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 2 Inch Wide
Item #: 04882320
Brand: Eaton Cutler-Hammer
Model #: HQP2050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
50
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
2
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 3 Pole, Plug In Type CH Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-6 AWG
Item #: 00104984
Brand: Eaton Cutler-Hammer
Model #: CH350
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type CH Circuit Breaker
Amperage
50
Number of Poles
3
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-6
Standards Met
Federal Specification W-C-375; UL 489
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 240 VAC, 3 Pole, Plug In Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 3 Inch Wide
Item #: 04882528
Brand: Eaton Cutler-Hammer
Model #: HQP3050H
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
50
Number of Poles
3
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Plug-in
Voltage
240 VAC
Wire Size (AWG)
14-4
Overall Depth (Inch)
2-3/8
Overall Height (Inch)
2-15/16
Overall Width (Inch)
3
Standards Met
CSA Listed; Federal Specification W-C-375b; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 250 VDC, 480 VAC, 2 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 2-3/4 Inch Wide
Item #: 04882965
Brand: Eaton Cutler-Hammer
Model #: EHD2050L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
50
Number of Poles
2
Breaking Capacity
14 kA @ 480 VAC; 18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
2-3/4
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 250 VDC, 480 VAC, 3 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04883070
Brand: Eaton Cutler-Hammer
Model #: EHD3050L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
50
Number of Poles
3
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
4-1/8
Overall Width (Decimal Inch)
4.1300
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 277/480 VAC, 2 Pole, Bolt On Molded Case Circuit Breaker - Thermal Magnetic Trip, 10-1/0 AWG, 66.7mm Deep x 4 Inch High x 2 Inch Wide
Item #: 04882684
Brand: Eaton Cutler-Hammer
Model #: GHB2050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
50
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
277/480 VAC
Wire Size (AWG)
10-1/0
Overall Depth (Decimal Inch)
2.6300
Overall Depth (mm)
66.70
Overall Height (mm)
101.60
Overall Height (Inch)
4
Overall Width (Inch)
2
Standards Met
CSA Listed; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 6 Circuits, 208/120 VAC, 125 Amp Main, 14-1/0 AWG, Flush, Indoor Main Lug Load Center - 3 Phase, 1 NEMA Rating, 11 Inch Wide x 3.69 Inch Deep x 13 Inch High
Item #: 00104075
Brand: Eaton Cutler-Hammer
Model #: CH6L3125FP
Exact Tooling IR#: 04
Product Specifications
Load Center Type
Main Lug
Number of Circuits
6
Main Amperage
125
Number of Phases
3
Voltage
208/120 VAC
NEMA Enclosure Rating
1
Body Material
Steel
Installation Orientation
Flush
Circuit Breaker Installation Type
Plug-in
Overall Depth (mm)
93.70
Overall Depth (Decimal Inch)
3.6900
Overall Height (Decimal Inch)
13
Overall Height (mm)
330.20
Overall Width (mm)
279.40
Overall Width (Decimal Inch)
11
Wire Size (AWG)
14-1/0
Recommended Environment
Indoor
Standards Met
CSA E3624 Certified; CSA E51287 Certified; CSA File LR87196 Certified; EC Article 373.8; Federal Specification W-C 375 b/Gen; NEMA; UL 489; UL Listed File E11713; UL Listed File E8741
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 6 Circuits, 208/120 VAC, 125 Amp Main, 14-1/0 AWG, Surface, Indoor Main Lug Load Center - 3 Phase, 1 NEMA Rating, 11 Inch Wide x 3.69 Inch Deep x 13 Inch High
Item #: 00104083
Brand: Eaton Cutler-Hammer
Model #: CH6L3125SP
Exact Tooling IR#: 04
Product Specifications
Load Center Type
Main Lug
Number of Circuits
6
Main Amperage
125
Number of Phases
3
Voltage
208/120 VAC
NEMA Enclosure Rating
1
Body Material
Steel
Installation Orientation
Surface
Circuit Breaker Installation Type
Plug-in
Overall Depth (mm)
93.70
Overall Depth (Decimal Inch)
3.6900
Overall Height (Decimal Inch)
13
Overall Height (mm)
330.20
Overall Width (mm)
279.40
Overall Width (Decimal Inch)
11
Wire Size (AWG)
14-1/0
Recommended Environment
Indoor
Standards Met
CSA E3624 Certified; CSA E51287 Certified; CSA File LR87196 Certified; EC Article 373.8; Federal Specification W-C 375 b/Gen; NEMA; UL 489; UL Listed File E11713; UL Listed File E8741
2% Off All Online Orders